RILEM has been organising symposia and workshops since its foundation, with more than 100 proceedings published. A quick glance at our online catalogue shows the diversity, importance and international scope of the topics.

To download an article FOR FREE, you must use your login and password if you have already been registered before and then select the article you are interested in on the Contents page of the publication. Non-members need to create an account.

 

Proceedings pro096 : XIII International Conference on Durability of Buiding Materials and Components XIII DBMC


Title: XIII International Conference on Durability of Building Materials and Components - XIII DBMC
Edited by M. Quattrone and V.M. John
ISBN: none
e-ISBN: 978-2-35158-149-0
Pages: 1147
Publication date: 2015


Contents


Preface
Author(s): Marco Quattrone, Vanderley M. John

ACCELERATED AGING TEST TO STUDY SELF CLEANING PROPERTIES OF PHOTOCATALYTIC POST TREATMENTS
Author(s): Garcia, G., Werle, A.P., Maranhão, F., Loh, K. and John, V.M.
Pages: 1-8

EVALUATION OF A MODULAR FRAMEWORK FOR PERFORMANCE-BASED DURABILITY ENGINEERING THROUGH ASSESSMENT OF A COASTAL REINFORCED CONCRETE STRUCTURE
Author(s): Flint, M. M. and Billington, S. L.
Pages: 9-16

PREDICTION OF THE SEALANT MODULUS CHANGE DUE TO OUTDOOR WEATHERING
Author(s): White, C.C., Tan, K. T., Hunston, D. L., Pintar, A. and Filliben, J.
Pages: 17-22

DURABILITY OF COOL AND CONVENTIONAL COLORED COATINGS AFTER SIX MONTHS EXPOSURE AT DIFFERENT ENVIRONMENTS
Author(s): Loh, K., Sato, N. M. N. and Liborio, I. M. S.
Pages: 23-29

IMPACT OF DIFFERENT EUROPEAN LOCAL CLIMATE CONDITIONS ON THE MOISTURE PERFORMANCE OF WOODEN COMMODITIES
Author(s): Bornemann, T., Brischke, C., Alfredsen, G., Humar, M. and Larsson-Brelid, P.
Pages: 30-37

NO CONCRETE IS SUSTAINABLE WITHOUT BEING DURABLE!
Author(s): De Schutter, G.
Pages: 38-44

TOWARDS PERFORMANCE BASED DURABILITY STANDARDS FOR WOOD IN CONSTRUCTION – PART 1: DELIVERING CUSTOMER SERVICE LIFE NEEDS
Author(s): Brischke, C., Suttie, E., Englund, F., Heisel, E., Jermer, J., Lorenzo, D., Polášek, M., Thelandersson, S. and Acker, J. V.
Pages: 45-52

TOWARDS PERFORMANCE BASED DURABILITY STANDARDS FOR WOOD IN CONSTRUCTION – PART 2: CONSIDERING MOISTURE RISKS IN WOODEN COMPONENTS
Author(s): Brischke, C., Meyer, L. and Suttie, E.
Pages: 53-60

REPEATED AUTOGENOUS HEALING IN CEMENTITIOUS COMPOSITES WITH MICROFIBRES AND SUPERABSORBENT POLYMERS
Author(s): De Snoeck, D., Debaecke, S. and De Belie, N.
Pages: 61-68

STRUCTURAL RECYCLED CONCRETE SCIENCE AND MARKET: A SUCCESS STORY
Author(s): Viviani, M., Dorthe, L. and Bugnon, M.
Pages: 69-76

IMPROVING THE RESILIENCE AND DURABILITY OF NEW ZEALAND’S BUILDINGS
Author(s): Jones, M. S., Marston, N. J., Shaw, P. and Li, Z.
Pages: 77-84

RE-ASSESSMENT OF NEW ZEALAND’S ATMOSPHERIC CORROSIVITY
Author(s): Marston, N. J., Li, Z., M. S. and Shaw, P.
Pages: 85-92

COMPARING THE INFLUENCE OF FLY ASH ON THE DURABILITY PROPERTIES OF PORTLAND CEMENT-BASED AND ALKALI ACTIVATED SLAG-BASED CONCRETES
Author(s): Provis, J. L., Bernal, S. A., Ismail, I., Nicolas, R. S., Brice, D. G., and van Deventer, J. S. J.
Pages: 93-100

ASSESSMENT OF THE HYDRATION CONSTANTS OF POST BLENDED BLAST FURNACE SLAG CEMENTS
Author(s): Visser, J., van Zon, Q., Beijersbergen, H., Hacquebord, A. and van Zwet, R.
Pages: 101-108

HYGROTHERMAL CONSEQUENCES OF APPLYING EXTERIOR AIR BARRIER SYSTEMS IN HIGHLY INSULATED WOOD-FRAME WALLS: A PARAMETER ANALYSIS
Author(s): Langmans, J., Vereecken, E. and Roels, S.
Pages: 109-116

THE DURABILITY OF BASALT FIBRES REINFORCED POLYMER (BFRP)
Author(s): Alaimo, G., Valenza, A., Enea, D., Fiore, V., Cracolici, A. and Spatafora, M.
Pages: 117-125

THE INFLUENCE OF CARBONATION ON DEICER SCALING RESISTANCE OF BLAST FURNACE SLAG CONCRETE (BFSC)
Author(s): Egüez, H. E., De Belie, N. and De Schutter, G.
Pages: 126-133

DISSOLUTION KINETICS EXPERIMENTS AS A METHOD TO ASSESS THE REACTIVITY OF SUPPLEMENTARY CEMENTITIOUS MATERIALS (SCMS): THE EFFECT OF SOLUTION COMPOSITION AND SCM STRUCTURE
Author(s): Snellings, R. and Scrivener, K.
Pages: 134-141

DURABILITY OF STRUCTURAL STEEL IN TRANSITIONAL FRAMED BUILDINGS
Author(s): Bentz, S. P., P.E., R.R.C., R.W.C., R.E.W.C., R.B.E.C., A.W.S.-C.W.I.and Guerrero, S. C., P.E.
Pages: 142-149

DEVELOPMENT OF EVALUATION METHOD BY SMALL CORE SPECIMEN FOR DETERIORATED FIBER CEMENT CORRUGATED SHEET AND SOME RESULTS OF ROOFS OVER STATION PLATFORMS
Author(s): Ishihara, S. and Tanaka, K.
Pages: 150-157

SERVICE LIFE PREDICTION AND EMBODY CO2 OF WOODEN BUILDINGS
Author(s): Nakajima, S., Yamaguchi, N., Koga, J., Nakajima, M., Momohara, I., Ohmura, W. and Tomura, S.
Pages: 158-165

PERFORMANCE ANALYSIS AND DURABILITY OF ENVIRONMENTAL AND ENERGY SUSTAINABILITY INTERVENTIONS ON EXISTING BUILDINGS
Author(s): Basiricò, T. and Cottone, A.
Pages: 166-173

FREEZE-THAW RESISTANCE OF ULTRA-HIGH PERFORMANCE CONCRETE IN NORMAL AND SEVERE CONDITIONS
Author(s): Jeroen, D., Boel, V. and De Schutter, G.
Pages: 174-181

GYPSUM EFFLORESCENCE ON CLAY BRICK MASONRY: FIELD SURVEY AND LITERATURE STUDY
Author(s): Chwast, J., Todorovic, J., Janssen, H. and Elsen, J.
Pages: 182-189

DECAY SUSCEPTIBILITY OF RAIN EXPOSED WOOD JOINTS – COMPARISON OF TWO DECAY MODELS
Author(s): Fredriksson, M., Wadsö, L. and Johansson, P.
Pages: 190-197

THE EFFICIENCY OF AUTONOMOUS CRACK HEALING OF MORTAR IN CHLORIDE SOLUTIONS
Author(s): Maes, M. and De Belie, N.
Pages: 198-205

DEGRADATION OF BRAZILIAN GYPSUM EXTERIOR WALLS DUE TO HYGROTHERMAL ACTION
Author(s): Santos, A., Delgado, J. M. P. Q. and Ramos, N. M. M.
Pages: 206-213

A NEW PERFORMANCE TEST TO ASSESS THE POTENTIAL DELETERIOUS EFFECT OF SULPHIDE-BEARING AGGREGATES FOR CONCRETE
Author(s): Duchesne, J., Rodrigues, A. and Fournier, B.
Pages: 214-221

VACUUM INSULATION TECHNOLOGY FOR BUILDINGS – A COMPARATIVE LCA STUDY OF A SWEDISH MULTIFAMILY BUILDING
Author(s): Gudmundsson, K., Karami, P. and Sjöström, C.
Pages: 222-230

SYSTEM MODEL OF MOULD GROWTH ON BUILDING MATERIALS
Author(s): Li, Y.
Pages: 231-235

ASSESSMENT OF DAMAGE DUE TO ALKALI-SILICA REACTION THROUGH MICROSCOPIC AND MECHANICAL TOOLS
Author(s): Sanchez, L. F. M., Fournier, B. Jolin M. and Bastien, J.
Pages: 236-243

AN IN-SITU AND LABORATORY STUDY OF THE EFFECT OF THE INTRINSIC PROPERTIES OF MORTARS ON THEIR POTENTIAL BIORECEPTIVITY
Author(s): Tran, T. H., Govin, A., Guyonnet, R., Grosseau, P., Lors, C., Damidot, D., Deves, O. and Ruot, B.
Pages: 244-251

INFLUENCE OF MATERIAL CHARACTERISTICS ON ELECTROCHEMICAL REALKALISATION OF CARBONATED CONCRETES
Author(s): Ribeiro, P. H. L. C., R. Meira, G. R. and Ferreira, P. R. R.
Pages: 252-259

ENVIRONMENTAL IMPACT ASSESSMENT OF FIRE RETARDANT TREATED WOOD USED IN EXTERIOR CLADDINGS
Author(s): Fufa, S. M. and Bohne, R. A.
Pages: 260-266

PERFORMANCE ANALYSIS OF WOOD SUBJECTED TO TREATMENTS MODIFIED WITH TITANIUM DIOXIDE AND CLAY NANOPARTICLES
Author(s): Fufa, S. M. and Jelle, B. P.
Pages: 267-274

PERFORMANCE OVER TIME OF ADHESIVE SYSTEMS FOR BONDING CERAMIC TILES ON FAÇADES – A CASE STUDY
Author(s): Freitas, V. P., Corvacho, H., Quintela, M. and Delgado, J. M. P. Q.
Pages: 275-282

HYGROTHERMAL PERFORMANCE OF A NATURALLY VENTILATED GYPSUM HOUSE – THE BRAZILIAN CLIMATE INFLUENCE
Author(s): Almeida, R. M. S. F., Freitas, V. P., Delgado, J. M. P. Q. and Paula, P.
Pages: 283-290

ACTUAL SERVICE LIFE PREDICTION OF BUILDING COMPONENTS
Author(s): Niels-Jørgen, A., Brandt, E. and Hansen, E. J. P.
Pages: 291-299

ALKALINE HYDROLYSIS OF POLYMERS IN CONTACT WITH CEMENT BASED MATERIALS
Author(s): Wadsö, L. and Karlsson, O. J.
Pages: 300-303

THE ENVIRONMENTAL BENEFITS OF SERVICE LIFE EXTENSION OF BUILDINGS COMPONENTS WITH TRANSFORMABLE DESIGN STRATEGIES
Author(s): Paduart, A., Temmerman, N. De and Vandenbroucke, M.
Pages: 304-311

EXPERIMENTAL STUDY ON CARBONATION AND CHLORIDE MIGRATION COEFFICIENTS OF SELF-COMPACTING CONCRETE (SCC) WITH BINARY AND TERNARY MIXTURES OF FLY ASH (FA) AND LIMESTONE FILLER (LF)
Author(s): Silva, P. R.and Brito, J.
Pages: 312-319

RESISTANT-BASED MOISTURE CONTENT MEASUREMENTS ON WATER REPELLENT TREATED MORTAR AND BRICK
Author(s): Sachse, K. A., Littmann, K., Fege, R. L. and Oremek, X.
Pages: 320-327

DURABILITY OF ROOF UNDERLAYS EXPOSED TO LONG TIME EXPOSURE UNDER IN-USE CONDITIONS
Author(s): Brandt, E. and Hansen, E. J. P.
Pages: 328-335

DRYING RATE AS A TRANSPORT INDEX FOR CONCRETE
Author(s): Villagrán-Zaccardi, Y. A., Alderete, N. M., Píttori, A. and Di Maio, A. A.
Pages: 336-343

DEVELOPMENT OF A METHODOLOGICAL PROCEDURE FOR THE DURABILITY EVALUATION OF EXISTING EXTERIOR FINISHINGS
Author(s): Erba, S., Daniotti, B. and Rosina, E.
Pages: 344-350

STOCHASTIC, DETERMINISTIC, STATISTICAL AND ARTIFICIAL INTELLIGENCE BASED MODELS TO PREDICT THE SERVICE LIFE OF RENDERED FACADES
Author(s): Silva, A., Gaspar, P. L. and Brito, J.
Pages: 351-358

INFLUENCE OF LIMESTONE POWDER ON THE SETTING AND HYDRATION OF CEMENT PASTE IN THE FRESH STATE
Author(s): Villagrán-Zaccardi, Y. A., Falcone, D. D. and Benito, D. E.
Pages: 359-366

IN-SITU MEASURMENTS OF MOISTURE CONTENT AND TEMPERATURE IN WOODEN CONSTRUCTIONS
Author(s): Sandberg, K., Dahlquist, S. and Pousette, A.
Pages: 367-374

EXPERIMENTAL EVALUATION OF PERFORMANCES OF DIFFERENT SOLUTIONS OF FINISHING FOR MASONRY BUILDINGS FOR DETERMINING DURABILITY
Author(s): Nicolella, M. and Iucolano, F.
Pages: 375-383

A METHODOLOGY FOR EVALUATING MAINTAINABILITY AS A TOOL FOR DURABLE AND SUSTAINABLE BUILDINGS
Author(s): Nicolella, M.
Pages: 384-391

INVESTIGATION OF THE EFFECTS OF LEACHING ON THE SCALING RESISTANCE OF CONCRETE
Author(s): Rosenqvist, M., Hassanzadeh, M., Long-Wei, `P. and Terzic, A.
Pages: 392-399

SERVICE LIFE OF INNOVATIVE SILOXANE COATING FORMULATIONS
Author(s): Enea, D. and Alaimo, G.
Pages: 400-408

EVALUATION OF RISING DAMP USING INFRARED THERMOGRAPHY
Author(s): Barreira, E., Delgado, J. M. P. Q. and Guimarães, A. S.
Pages: 409-416

EFFECT OF CONFINEMENT AND CONCRETE STRENGTH UPON CRACK BEHAVIOR INDUCED BY CORROSION-PRODUCT EXPANSION
Author(s): Shinohara, Y. and Aryanto, A.
Pages: 417-424

A NEW TEST METHOD TO EVALUATE THE RESISTANCE OF CEMENTITIOUS MATERIALS EXPOSED TO BIOGENIC ATTACK IN SEWER NETWORKS
Author(s): Lavigne, M. P., Bertron, A., Cockx, A., Jean-Noël, F., Escadeillas, G. and Paul, E.
Pages: 425-433

DURABILITY OF QUATERNARY CEMENTS CONTAINING CALCAREOUS FLY ASH, SLAG AND LIMESTONE
Author(s): Durdziński, P. T., Haha, M. B. and Scrivener, K. L.
Pages: 434-440

RATING BUILDING ASSET DEGRADATION WITH EFFICIENCY INDEXES
Author(s): Re Cecconi, F., Dejaco, M. C. and Maltese, S.
Pages: 441-448

DURABILITY OF FIBRE-CEMENT ROOFING CORRUGATED SHEETS
Author(s): Fiorelli, J., Savastano Junior, H., Tonoli, G. H. D. and Santos, S. F.
Pages: 449-457

THERMAL SHOCK EFFECTS ON BONDING OF CEMENT MORTAR RENDERINGS
Author(s): Esquivel, J. F. T. and Barros, M.
Pages: 458-466

EFFECT OF CARBONATION ON THE CHLORIDE DIFFUSION OF MORTAR SPECIMENS EXPOSED TO CYCLIC WETTING AND DRYING
Author(s): Malheiro, R., Camões, A., Ferreira, R. M., Meira, G. and Amorim, T.
Pages: 467-474

ACCELERATED CLIMATE AGEING OF WOOD SURFACE TREATMENTS AND THEIR EVALUATION BY FOURIER TRANSFORM INFRARED SPECTROSCOPY
Author(s): Jelle, B. P., Fufa, S. M. and Olsen, M. B.
Pages: 475-482

NANORENDERS ON BUILDING FACADES: TECHNICAL, ECONOMIC AND ENVIRONMENTAL PERFORMANCE
Author(s): Soares, A., Flores-Colen, I. and Brito, J.
Pages: 483-490

AN INVESTIGATION OF THE EFFECTIVENESS AND DURABILITY CHARACTERISTIC OF BIOMASS ASHES AS POZZOLANIC MATERIALS
Author(s): Demis, S., Rodrigues, C. S., Santos, L. A. and Papadakis, V. G.
Pages: 491-498

MULTI-PHYSICS MODELLING FOR DURABILITY EVALUATION OF ETICS
Author(s): Daniotti, B., Re Cecconi, F., Paolini, R., Cocchetti, G., Galliano, R. and Cornaggia, A.
Pages: 499-506

MICROSTRUCTURE DEVELOPMENT IN SLAG-CEMENT SYSTEMS
Author(s): Berodier, E. and Scrivener, K.
Pages: 507-511

A NUMERICAL STUDY OF THE INFLUENCE OF THE HYDRAULIC INTERFACE CONTACT ON THE HYGRIC PERFORMANCE OF A MULTI-LAYERED SYSTEM
Author(s): Vereecken, E. and Roels, S.
Pages: 512-519

EVALUATION OF DAMAGE OF BUILDING FACADES IN BRASILIA
Author(s): Bauer, E., Kraus, E., Silva, M. N. B. and Zanoni, V. A. G.
Pages: 520-526

ACCELERATED AGEING AND CHARACTERIZATION OF EXPANDING WEATHER STRIPPING FOAM
Author(s): Jelle, B. P., Jorun-Marie, H., Gao, T., Bugten, A., Rognvik, E. and Kvalvik, M.
Pages: 527-534

DEVELOPMENT OF A 2D NUMERICAL MODEL FOR RAINWATER RUNOFF ON VERTICAL PLANES
Author(s): Bossche, N. van D., Ge, H., Vogelaere, T. D., Pacco, M. and Janssens, A.
Pages: 535-542

AIRTIGHTNESS OF THE WINDOW–WALL INTERFACE IN WOODFRAME WALLS
Author(s): Bracke, W., Devos, L., Maertens, S., Bossche, N. Van D. and Janssens, A.
Pages: 543-553

A MODEL OF CARBONATION AND A TECHNIQUE TO DETERMINE THE DEGREE OF CARBONATION
Author(s): Fridh, K. and Lars-Olof, N.
Pages: 554-560

NONDESTRUCTIVE DETERMINATION OF CHLORIDE ION USING Ag/AgCl ELECTRODE PREPARED BY ELECTROCHEMICAL ANODIZATION
Author(s): Pargar, F., Koleva, D. A., Copuroglu, O., Koenders, E. A. B. and Breugel, K. van
Pages: 561-568

MODIFICATION OF CELLULOSE-CEMENT COMPOSITES BY ADMIXTURE OF SUGAR CANE BAGASSE ASH
Author(s): Rodrigues, C. S., Zukowski, B., Figueiredo, S. C. and Santos, L. A.
Pages: 569-576

ACCELERATED AGEING AND DURABILITY OF DOUBLE-GLAZED SEALED INSULATING WINDOW PANES
Author(s): Asphaug, S. K., Jelle, B. P., Gullbrekken, L. and Uvsløkk, S.
Pages: 577-584

TORTUOSITY AND ELECTRICAL IMPEDANCE OF CONTAMINATED MORTARS WITH NITRATES OF Cr3+, Pb2+, AND Zn2+
Author(s): Venâncio, C., Rocha, J. C. and Cheriaf, M.
Pages: 585-592

THE INFLUENCE OF WETTING PRIOR AND ADDITION OF FINES IN PRODUCED MORTARS WITH RECYCLED AGGREGATE
Author(s): Jochem, L. F., Rocha, J. C. and Cheriaf, M.
Pages: 593-598

MOULD RISK ASSESSMENT FOR THERMAL BRIDGES: WHAT IS THE IMPACT OF THE MOULD PREDICTION MODEL?
Author(s): Vereecken, E. and Roels, S.
Pages: 599-606

A METHOD FOR BLIND VALIDATION OF HYGROTHERMAL CALCULATION TOOLS
Author(s): Mundt-Petersen, S. O. and Harderup, L.-E.
Pages: 607-615

METHODS FOR COMPENSATE LACK OF CLIMATE BONDARY DATA
Author(s): Mundt-Petersen, S. O. and Wallentén, P.
Pages: 616-624

FRAGILITY CURVES FOR THIN-WALLED COLD-FORMED STEEL WALL FRAMES WITH DIFFERENT SHEATHING SYSTEMS AFFECTED BY GROUND SETTLEMENTS DUE TO LAND SUBSIDENCE
Author(s): Ortiz, J. A., Hernandez, L. A., Hernandez, M., Pacheco, J., Soto, J. J., Ramos, J., Fernandez, R. and Soto, M. A.
Pages: 625-632

SELF-HEALING OF SELF-COMPACTING CONCRETES MADE WITH BRAZILIAN BLAST FURNACE SLAG CEMENTS ACTIVATED BY CRYSTALLINE CATALYST
Author(s): Takagi, E. M., Lima, M. G. and Helene, P.
Pages: 633-640

DURABILITY ASSESSMENT OF INNOVATIVE BUILDING PRODUCTS IN BRAZIL: EXAMPLE OF PVC COMPONENTS USED AS STAY-IN-PLACE FORMS AND FINISHING OF CONCRETE WALLS
Author(s): Oliveira, L. A, Rodolfo Junior, A., Fontenelle, J. H. and Mitidieri Filho, C. V.
Pages: 641-649

SULFATE INGRESS AND MICROSTRUCTURAL CHANGES IN CEMENT PASTES AT EARLY AGE
Author(s): Ragoug, R., Omikrine-Metalssi, O., Divet, L., Deman, A., Barberon, F., Gegout, P., Baroghel-Bouny, V. and Roussel, N.
Pages: 650-655

DETERMINATION OF CRITERIA FOR THE EXPLORATION AND FOR OBTAINING INDICATORS IN EVOLUTIONAL ANALYSIS OF DEGRADATION IN URBAN FACADES
Author(s): Gibert, V., Serrat, C. and Casas, J. R.
Pages: 656-663

MAINTENANCE AND REFURBISHMENT; MARKET PRICE AND FIXED ASSETS VALUE
Author(s): Marteinsson, B.
Pages: 664-669

CHEMICAL TREATMENT WITH OXALIC ACID TO IMPROVE THE DURABILITY OF CEMENT-BASED MATERIALS IN ACID ENVIRONMENTS
Author(s): Voegel, C., Bertron, A., Erable, B. and Escadeillas, G.
Pages: 670-678

METHOD DEVELOPMENT FOR THE PARTICLE SIZE ANALYSIS OF SUPPLEMENTARY CEMENTITIOUS MATERIALS
Author(s): Arvaniti, E. C. and De Belie, N.
Pages: 679-686

SYNTHESIS, CHARACTERIZATION AND DURABILITY OF SELFCLEANING ANTIREFLECTION COATINGS FOR GLAZING APPLICATIONS
Author(s): Gao, T. and Jelle, B. P.
Pages: 687-694

EVALUATION OF CHLORIDE ION PENETRATION METHODS IN CONCRETE WITH RECYCLED CONCRETE AGGREGATE AND RICE HUSK ASH
Author(s): Kulakowski, M. P., Fedumenti, M. B., Kazmierczak, C. S. and Mancio, M.
Pages: 695-702

PERFORMANCE OF THE COPPER TREATED, AND NATURALLY DURABLE WOOD IN LABORATORY AND OUTDOOR CONDITIONS
Author(s): Humar, M., Lesar, B. and Thaler, N.
Pages: 703-710

FROM LAB SCALE TO IN SITU APPLICATIONS – THE ASCENT OF A BIOGENIC CARBONATE BASED SURFACE TREATMENT
Author(s): Muynck, W. D., Boon, N. and De Belie, N.
Pages: 711-718

MICROSCOPY AND COMPUTED MICRO-TOMOGRAPHY FOR EVALUATION OF MICROBIAL SELF-HEALING IN CONCRETE
Author(s): Wang, J., Tittelboom, K. van and De Belie, N.
Pages: 719-726

MICROBIALLY INFLUENCED DEGRADATION OF CEMENT-BASED MATERIALS IN BIOGAS PRODUCTION ENVIRONMENTS
Author(s): Voegel, C., Bertron, A. and Erable, B.
Pages: 727-736

DURABILITY PROBLEMS WITH ZINC CLADDED ROOFS DUE TO INPROPER UNDERLAYS
Author(s): Bunch-Nielsen, T. and Brandt, E.
Pages: 737-743

THE HIGH SCHOOL "GIUSTINO FORTUNATO" IN RIONERO IN VULTURE (POTENZA, ITALY): HOW TO REFURBISH AN HIGHER EDUCATION INSTITUTE MADE IN BRUTALIST ARCHITECTURE OF ‘80, LEADING IT TO BE A NZEB AND PRESERVING ITS FORMAL FEATURES
Author(s): Lembo, F. and Marino, F. P. R.
Pages: 744-751

DURABILITY AND MICROSTRUCTURE OF MORTAR WITH CALCINED MARL AS SUPPLEMENTARY CEMENTING MATERIAL
Author(s): Justnes, H. and Østnor, T. A.
Pages: 752-761

EMBODIED ENERGY AS A TOOL TO SUSTAINABLE STRATEGIC DECISIONS ON REFURBISHMENT
Author(s): Gaspar, P. L. and Santos, A. L.
Pages: 762-769

THE INFLUENCE OF THE SUBSTRATE CHARACTERISTICS ON THE BEHAVIOR OF THE MORTAR
Author(s): Torres, I., Veiga, R. and Freitas, V. P.
Pages: 770-777

DURABILITY OF PVC ROOFING AND WATERPROOFING MEMBRANES – CASE STUDIES AFTER 40+ YEARS OF EXPOSURE
Author(s): Beer, H. R. and Bonnet, M.
Pages: 778-785

DURABILITY OF REINFORCED CONCRETE MADE WITH LOW CLINKER, TERNARY BLEND CEMENT
Author(s): Martirena, J. F., Vizcaíno, L. M., Antoni, M. G., Henocq, P., Alujas, A. and Scrivener, K. L.
Pages: 786-793

PULL-OUT TESTS OF CAST-IN-PLACE ANCHOR STUDS WITH DIFFERENT EMBEDMENT DEPTHS
Author(s): Delhomme, F., Roure, T., Arrieta, B., Trunfio, R. and Limam, A.
Pages: 794-800

SERVICE LIFE ASSESSMENT OF CONCRETE STRUCTURES BASED ON SITE TESTING
Author(s): Torrent, R. J. and Luco, L. F.
Pages: 801-809

ENVIRONMENTAL SUSTAINABILITY PERFORMANCE OF RESIDENTIAL BUILDINGS' THERMAL RETROFITS
Author(s): Cetiner, I. and Edis, E.
Pages: 810-817

SPECIFICATIONS FOR EXTERNAL RENDERS AND INTERNAL PLASTERS: A REVIEW ON DURABILITY ASSESSMENT
Author(s): Sá, A. V., Abrantes, V. and Sousa, H.
Pages: 818-825

ANISOTROPIC EXPANSION OF ASR AFFECTED CONCRETE PRISM SPECIMENS
Author(s): Gautam, B. P. and Panesar, D. K.
Pages: 826-833

THE INFLUENCE OF CRACK WIDTH ON THE DURABILITY OF REINFORCED CONCRETE STRUCTURES
Author(s): Blagojević, A., Koleva, D. A. and Walraven, J. C.
Pages: 834-841

TIME-DEPENDENT PASSIVE INFRARED THERMOGRAPHIC INSPECTION OF FACADES
Author(s): Edis, E., Flores-Colen, I. and Brito, J.
Pages: 842-849

STUDY OF WOOD WASTE ASH AS A POZZOLANIC ADDITION
Author(s): Matos, A. M., Ramos, T. and Sousa-Coutinho, J.
Pages: 850-857

PROBABILISTIC MODELING DURABILITY OF WOODEN WINDOW FRAMES
Author(s): Straalen, I. J. J. van, Abspoel-Bukman, L. M., Courage, W. M. G. and Mennink, J.
Pages: 858-865

DURABILITY OF JOINTED REINFORCED CONCRETE PAVEMENTS UNDER SEVER EXPOSURE CONDITIONS: A CASE STUDY IN IRAN
Author(s): Arabali, P. and Shekarchi, M.
Pages: 866-873

RESPONSE MONITORING OF NATIONAL HERITAGE FIVE STORY WOODEN PAGODA BY THE USE OF IMAGE PROCESSING
Author(s): Mikoshiba, T., Niitsu, Y., Hanazato, T. and Minowa, C.
Pages: 874-881

OUTDOOR EXPOSURE TEST OF PHOTOCATALYST-COATED MATERIALS IN VARIOUS TEST LOCATIONS WITHIN ASIA
Author(s): Toyoda, H., Murakami, T., Sano, T. and Takeuchi, K.
Pages: 882-888

REHABILITATION OF A WASTEWATER TREATMENT PLANT
Author(s): Barreto, M. P. and Torres, I.
Pages: 889-896

BACTERIOGENICALLY INDUCED SULFURIC ACID ATTACK ON CONCRETE IN AN AUSTRIAN SEWER SYSTEM
Author(s): Grengg, C., Mittermayr, F., Baldermann, A., Böttcher, M. E., Leis, A., Koraimann, G. and Dietzel, M.
Pages: 897-903

DURABILITY OF CEMENT-REDUCED ECO-FRIENDLY CONCRETES AGAINST SULFATE ATTACK
Author(s): Hainer, S., Rezvani, M., Baldermann, A., Proske, T. and Mittermayr, F.
Pages: 904-911

PHYSICAL AND CHEMICAL PROPERTIES OF CEMENTITIOUS MATERIALS UNDERGOING ACCELERATED DECALCIFICATION
Author(s): Babaahmadi, A., Tang, L. and Abbas, Z.
Pages: 912-919

EVOLUTION OF THE CEMENT MORTAR MICROSTRUCTURE CAUSED BY SALT CRYSTALLIZATION AND WATER FREEZING INVESTIGATED BY MULTICYCLE MERCURY INTRUSION POROSIMETRY
Author(s): Grymin, W., Koniorczyk, M., Konca, P., Marciniak, A. and Gawin, D.
Pages: 920-927

DURABILITY PERFORMANCE OF CONCRETE WITH GLASS POWDER AS SUPPLEMENTARY CEMENTITIOUS MATERIAL
Author(s): Du, H. and Tan, K. H.
Pages: 928-935

USE OF 2-D NANO-PARTICLE TO ENHANCE THE CONCRETE RESISTANCE TO CHLORIDE INGRESS
Author(s): Du, H., Gao, H. J. and Pang, S. D.
Pages: 936-943

CHARACTERISTICS OF IN-SERVICE, 30-YEAR-OLD EPDM ROOF MEMBRANE
Author(s): Hutchinson, T. W., Trischuk, K. and Paroli, R. M.
Pages: 944-949

EVALUATION OF CLUSTERED DISTRIBUTION OF SUPERABSORBENT POLYMERS AND ITS RELATION TO AUTOGENOUS SHRINKAGE BEHAVIOUR OF INTERNALLY CURED MORTARS
Author(s): Yokota, K. and Shin-ichi, I.
Pages: 950-957

HAIL PROTECTED ETFE-ROOF LIGHTS FOR THE NEW ELEPHANT PARK BUILIDING OF ZOO ZURICH
Author(s): Flüeler, P., Kübler, W. and Hohl, A.
Pages: 958-965

CHARACTERIZATION OF MORTARSWITH CERAMIC RESIDUES
Author(s): Matias, G., Torres, I. and Faria, P.
Pages: 966-973

STUDY OF THE DURABILITY OF MORTAR FOR STRUCTURAL CONCRETE MADE WITH FINE POWDER OF WHITE GLASS
Author(s): Sales, F. A., Sales, R. B. C., Corrêa, E. C. S., Molhallem, N. D. S. and Aguilar, M. T. P.
Pages: 974-982

ADHESIVE TAPES FOR BUILDING PURPOSES: FRAMEWORK FOR EVALUATION OF PERFORMANCE AND DURABILITY
Author(s): Fufa, S. M., Kvalvik, M. and Rüther, P.
Pages: 983-990

INVESTIGATION METHODS OF THE RESISTANCE OF UHPC TO CHEMICAL ATTACK AND ITS CLASSIFICATION IN THE EXPOSURE CLASSES OF THE EUROPEAN STANDARD
Author(s): Schmidt, H., Schmidt-Döhl, F., Franke, L. and Deckelmann, G.
Pages: 991-998

REDUCTION OF AUTOGENOUS SHRINKAGE IN OPC AND BFSC PASTES WITH INTERNAL CURING
Author(s): Wyrzykowski, M. and Lura, P.
Pages: 999-1005

QUALITY CONTROL OF REINFORCED CONCRETE STRUCTURES FOR DURABILITY
Author(s): Nganga, G. W., Alexander, M. G. and Beushausen, H. D.
Pages: 1006-1014

A NUMERICAL INVESTIGATION OF AGGREGATE SHAPE EFFECT ON THE DIFFUSIVITY OF MORTAR BASED ON ELLIPSOIDAL PARTICLE PACKING
Author(s): Liu, L., Chen, H. and Xu, W.
Pages: 1015-1022

BIOGENIC CORROSION OF CONCRETE SEWER PIPES: A REVIEW OF THE PERFORMANCE OF CEMENTITIOUS MATERIALS
Author(s): Kiliswa, M. W. and Alexander, M. G.
Pages: 1023-1030

THE EFFECTS OF VARIOUS MOULD RELEASE TECHNOLOGIES ON CONCRETE SURFACE FINISH
Author(s): Coventry, K. A., Richardson, A. E. and Baines, C.
Pages: 1031-1040

INFLUENCE OF SERVICE LIFE ON BUILDING LCA
Author(s): Hoxha, E., Bazzana, M. Habert, G., Chevalier, J. and Le Roy, R.
Pages: 1041-1048

CHARACTERIZATION THROUGH MERCURY POROSIMETRY OF TORTUOSITY FACTORS OF CONCRETES CONTAINING MINERAL ADDITIONS
Author(s): Andrade, C., Rebolledo, N., Menéndez,E., Perez, R. and Baz, M.
Pages: 1049-1056

INFLUENCE OF REDISPERSIBLE POLYMER POWDERS ON DAMAGE MECHANISMS OF ETICS RENDER MORTARS
Author(s): Valdès, L., Aulagnier, M., Prat, E. and Chaouche, M.
Pages: 1057-1064

TRANSPORT PROPERTIES OF RECYCLED FINE AGGREGATE CONCRETES
Author(s): Zega, C. J., Sosa, M. E. and Di Maio, A. A.
Pages: 1065-1072

EVOLUTION OF HYDRATION OF CEMENTS WITH COAL BOTTOM AND FLY ASH BY NON – DESTRUCTIVE TECHNIQUES AND POROSIMETRY
Author(s): Menéndez, E., Alvaro, A. M. and Andrade, C.
Pages: 1073-1080

MEASURING WATER SORPTION ISOTHERM OF MORTAR CONTAINING CHLORIDE
Author(s): Taher, A., Arends, T., van der Zanden, A. J. J. and Brouwers, H. J. H.
Pages: 1081-1088

BACTERIAL CONCRETE: A BIOLOGICAL APPROACH TO REDUCED PERMEABILITY
Author(s): Richardson, A., Coventry, K. and Scott, A.
Pages: 1089-1098

DEVELOPMENT AND STANDARDIZATION OF RAPID METHODS FOR ASSESSING THE FLUID PENENTRATION RESISTANCE OF CONCRETE
Author(s): Hooton, R. D., Charmchi, G. and Karkar, E.
Pages: 1099-1105

ASSESSMENT OF CHLORIDE INGRESS IN BLENDED CEMENT WITH COMBINED ADDITION OF CALCINED CLAYS AND LIMESTONE
Author(s): Antoni, M., Henocq, P., Kazemi-Kamyab, H., Favier, A., Martirena, F. and Scrivener, K.
Pages: 1106-1113

CHLORIDE PENETRATION DEPENDENCY ON FREEZE-THAW CYCLES
Author(s): Ferreira, M., Leivo, M., Kuosa, H., Makkonen, L. and Lange, D.
Pages: 1114-1121

COMBINING GEOGRAPHICAL INFORMATION SYSTEMS AND MULTI-SCALE MODELLING TO PREDICT SERVICE LIFE
Author(s): Cole, I. S. and Ganther, W. D.
Pages: 1122-1128

SUSTAINING A HISTORIC HIGH-RISE STRUCTURE
Author(s): Mahjoub, N. A. P. E., Stringer, M. P . E. and Tremayne, B. S. E.
Pages: 1129-1136

EFFECT OF CEMENT CONTENT ON CONCRETE DURABILITY
Author(s): Katz, A., Bentur, A., and Wasserman, R.
Pages: 1137-1142

FULL PROCEEDINGS
Author(s):
Pages: 1-1147