Publications

275

The Marsh Cone as a viscometer: theoretical analysis and practical limits



Title: The Marsh Cone as a viscometer: theoretical analysis and practical limits
Author(s): R. Le Roy, N. Roussel
Paper category : journal
Serial title: Materials and Structures
Abreviated Serial title: Mater. Struct.
ISSN: 1359-5997
Publisher: RILEM Publications SARL
Volume: 38
Issue: 275
Issue date: 2005-01-01
Publication year: 2005
Pages: 25 - 30
Total Pages: 6
Nb references: 8
Language: English


Abstract: In this study, we have investigated the possibility of using the Marsh cone as a viscometer.
Rheological measurements along with digital image recording of Marsh cone flow on glycerol-water mixes were carried out.
The equations needed to solve the flow problem are written in the case of a purely Newtonian viscous fluid.
We show that flow time can be directly linked to the Newtonian viscosity.
Flow time is proportional to viscosity.
The Marsh cone is then used to test several cement pastes and measured flow time is compared to predicted flow time.
The correlation between flow time and cement pastes apparent viscosity stays valid only for no yield stress cement pastes and for flow time higher than about 15 s.


Online publication: 2004-12-23
Classification: Scientific Reports
Publication type : full_text
Public price (Euros): 0.00
doi: 10.1617/14115


>> You must be connected to view the paper. You can register for free if you are not a member