Publications

Pro106

Behaviour of headed shear stud connectors in composite beams with UHPFRC connection



Author(s) : M. Gascon, B. Massicotte, F. Lagier
Paper category : Proceedings
Book title : UHPFRC 2017 Designing and Building with UHPFRC: New large-scale implementations, recent technical advances, experience and standards
Editor(s) : F. Toutlemonde & J. ResplendinoT.Ch.
Print-ISBN : 978-2-35158-166-7
e-ISBN : 978-2-35158-167-4
Publisher : RILEM Publications SARL
Publication year : 2017
Pages: 471 - 480
Total Pages : 10
Language : English


Abstract: The outstanding properties of ultra-high performance fibre reinforced concrete (UHPFRC) promote innovative applications. The aim of the experimental program presented in this paper is to determine the performance in terms of capacity and ductility of the headed shear stud connectors in UHPFRC joints using a single side push-out test. A total of 5 specimens were tested with various parameters including, concrete type, haunches, stud length. The specimen performance related to the concrete type is considered. Test results showed that the failure mode of composite girder with UHPFRC connection is always by stud fracture through the weld collar. Compared with ordinary concrete, using shear connectors in UHPFRC leads to an increase in the load carrying capacity while presenting high ductility


Online publication : 2017
Publication type : full_text
Public price (Euros) : 0.00


>> You must be connected to view the paper. You can register for free if you are not a member