Shear bond strength in repaired concrete structures



Title: Shear bond strength in repaired concrete structures
Author(s): J. Silfwerbrand
Paper category : journal
Serial title: Materials and Structures
Abreviated Serial title: Mater. Struct.
ISSN: 1359-5997
Publisher: RILEM Publications SARL
Volume: 36
Issue: 260
Issue date: 2003-07-01
Publication year: 2003
Pages: 419 - 424
Total Pages: 6
Nb references: 19
Language: English


Abstract: A good bond between old and new concrete is necessary for a successful repair of concrete structures.
The bond is usually determined through pure tension tests, e.
g.
, the common pull off test.
However, in most applications, the shear bond strength is more interested.
A test apparatus for torsion tests has been developed.
Laboratory and field tests have been carried out on cast in place concrete and shotcrete repairs.
For waterjetted surfaces, the obtained shear bond strength exceeds 3 MPa, i.
e.
, considerably more than the tensile bond strength which usually varies between 1 and 2 MPa.
The shear bond strength is also markedly higher than design strength values found in international codes.


Online publication: 2003-05-27
Classification: Scientific Reports
Publication type : full_text
Public price (Euros): 0.00
doi: 10.1617/13859